Zimed offer varied range of Ventilator Machines used for emergency clinical resuscitation and. respiratory therapy. Our neonatal ventilator machine is specially designed for new born babies with respiratory disorder. They are highly stable and meet intensive care unit requirements.  Our products are ISO and CE approved and certified.

compare product
  • Specification

    Tidal volume 10 - 1500 ml
    Ventilation mode A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, Spont, manual
    Respiratory rate 1 to 99 bpm
    I:E ratio 4:1-1:4
    Air compressor
    Inspiratory time
    Minute volume ≥ 18 L
    Display 10.4 inch (TFT)
    Pressure limit 1.0 kPa to 6.0 kPa
    Medical grade O2 supply
    SIGH
    Over pressure relief
    Adjustable oxygen concentration 45 - 100 %
    Backup power supply 4 hours
  • Features

    • Working mode: Closed, semi-closed and semi-open
      TFT Display: pressure-time, frequency-time, pressure-volume, frequency-volume and any 2 waveform
      Pressure trigger and flow trigger
      Monitor parameter: tidal volume, respiratory rate, airway pressure, I: E ratio, inspiratory expiratory status etc
      9 level adjustable humidifier
      Environmentally friendly
      Alarm system: audible and/or visual during any feature failure
      Before starting to perform automatically check the initial functions, automatic calibration is done
compare product
  • Specification

    Tidal volume 10 - 1500 ml
    Ventilation mode A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, Spont, manual
    Respiratory rate 1 to 99 bpm
    I:E ratio 4:1-1:4
    Air compressor Yes
    Inspiratory time
    Minute volume ≥ 18 L
    Display 10.4 inch (TFT)
    Pressure limit 1.0 kPa to 6.0 kPa
    Medical grade O2 supply
    SIGH
    Over pressure relief
    Adjustable oxygen concentration 21 - 100 %
    Backup power supply 4 hours
  • Features

    • Working mode: Closed, semi-closed and semi-open
      TFT Display: pressure-time, frequency-time, pressure-volume, frequency-volume and any 2 waveform
      Pressure trigger and flow trigger
      Monitor parameter: tidal volume, respiratory rate, airway pressure, I: E ratio, inspiratory expiratory status etc
      9 level adjustable humidifier
      Environmentally friendly
      Alarm system: audible and/or visual during any feature failure
      Before starting to perform automatically check the initial functions, automatic calibration is done
compare product
  • Specification

    Tidal volume 50 - 1500 ml
    Ventilation mode A/C, IPPV, SIPPV, IMV, SIMV, standby, SPONT, manual
    Respiratory rate 1 to 99 bpm
    I:E ratio 4:1-1:4
    Air compressor
    Inspiratory time
    Minute volume ≥ 18 L
    Display 10.4 inch (TFT)
    Pressure limit 1.0 kPa to 6.0 kPa
    Medical grade O2 supply 280 ̴ 600 kPa
    SIGH
    Over pressure relief
    Adjustable oxygen concentration 45 - 100 %
    Backup power supply 4 hours
  • Features

    • Working mode: closed, semi closed and semi open
      TFT Display: pressure-time, frequency-time, wave forms
      Monitor parameter: tidal volume, respiration rate, airway pressure, I:E ratio, Inspiration Expiration status
      9 level adjustable humidifier
      Environmentally friendly
      Backup power supply during power failure
compare product
  • Specification

    Tidal volume 50 - 1500 ml
    Ventilation mode A/C, IPPV, SIPPV, IMV, SIMV, standby, SPONT, manual
    Respiratory rate 1 to 99 bpm
    I:E ratio 4:1-1:4
    Air compressor Yes
    Inspiratory time
    Minute volume ≥ 18 L
    Display 10.4 inch (TFT)
    Pressure limit 1.0 kPa to 6.0 kPa
    Medical grade O2 supply 280 ̴ 600 kPa
    SIGH
    Over pressure relief
    Adjustable oxygen concentration 21 - 100 %
    Backup power supply 4 hours
  • Features

    • Working mode: closed, semi closed and semi open
      TFT Display: pressure-time, frequency-time, wave forms
      Monitor parameter: tidal volume, respiration rate, airway pressure, I:E ratio, Inspiration Expiration status
      9 level adjustable humidifier
      Environmentally friendly
      Backup power supply during power failure
compare product
  • Specification

    Tidal volume 50 - 1500 ml
    Ventilation mode A/C, IPPV, SIPPV, IMV, SIMV, Manual
    Respiratory rate 6 to 60 bpm
    I:E ratio 1:1.5 - 1:3.0
    Air compressor
    Inspiratory time
    Minute volume
    Display LED
    Pressure limit 1.0 kPa to 6.0 kPa
    Medical grade O2 supply 280 ̴ 600 kPa
    SIGH 1 sigh breath in every 80 - 120 breaths
    Over pressure relief
    Adjustable oxygen concentration
    Backup power supply 4 hours
  • Features

    • Tactile analog parameter controls
      High precession pressure and flow sensor
      Non hazardous
      User friendly
      Backup power supply during power failure
      9 level adjustable humidifier
compare product
  • Specification

    Tidal volume
    Ventilation mode
    Respiratory rate IPPV: 5 to 60 bpm,
    SIMV: 1 ̴ 12 bpm
    I:E ratio
    Air compressor
    Inspiratory time 0.2 ̴ 3 sec
    Minute volume 0-40 L/min
    Display
    Pressure limit 1 to 9 kPa
    Medical grade O2 supply
    SIGH
    Over pressure relief
    Adjustable oxygen concentration 21-100 %
    Backup power supply
  • Features

    • Multipurpose : adult and neonate
      Ventilation mode-1) Adult: IPPV(VC)/(PC), SIMV, SIMV+PSV, CPAP, PSV 2) Neonate: IPPV (PC), IMV, CPAP continues flow, limited pressure, Time cycle 3) Emergency: IPPA (PC) constant pressure
      Inspiratory flow rate: 1) Adult: 10 to 120 L/min (inspiratory phase) 2) Infant: 4 to 24 L/min (continuous)
      Respiratory rate, minute volume, tidal volume are visible in the ventilator monitor
      Maximum, mean and plateau pressures are observed in the airway pressure monitor
      Presence of alarm system
      Backup power supply
compare product
  • Specification

    Tidal volume 10 - 300 ml
    Ventilation mode CMV, IMV, CPAP, Manual
    Respiratory rate 1 to 120 bpm
    I:E ratio 1:0.1 - 1:9.9
    Air compressor
    Inspiratory time
    Minute volume ≥ 5 L/min
    Display
    Pressure limit
    Medical grade O2 supply
    SIGH
    Over pressure relief
    Adjustable oxygen concentration 21 - 100 %
    Backup power supply
  • Features

    • Compact and highly reliable
      Innovative functions, convenient operation with low tidal volume
      Essential instrument in emergency and ICU rooms
      Audible/ visual alarm systems
      Backup power supply
compare product
  • Specification

    Tidal volume 50 - 1000 ml
    Ventilation mode IPPV
    Respiratory rate 10,15,20,25,30,35 bpm
    I:E ratio
    Air compressor
    Inspiratory time
    Minute volume
    Display LED
    Pressure limit
    Medical grade O2 supply
    SIGH
    Over pressure relief ≤ 60 hpa
    Adjustable oxygen concentration
    Backup power supply
  • Features

    • Portable ventilator machine
      Multifunctional
      It consist ventilator, O2 cylinder, breathe circuit, special bracket
      More accuracy
      Easy to carry ( transport )
compare product
  • Specification

    Tidal volume 50 - 1200 ml
    Ventilation mode CMV(IPPV),SIPPV(A/C) SIMV, Spont, PEEP
    Respiratory rate 1 to 100 bpm
    I:E ratio
    Air compressor
    Inspiratory time
    Minute volume
    Display LED
    Pressure limit
    Medical grade O2 supply
    SIGH
    Over pressure relief ≤ 72 hpa
    Adjustable oxygen concentration 40 - 100 %
    Backup power supply
  • Features

    • Portable ventilator machine
      Multifunctional
      It consist ventilator, O2 cylinder, breathe circuit, special bracket
      More accuracy
      Easy to carry ( transport )
compare product
  • Specification

    Tidal volume 50 - 1200 ml
    Ventilation mode C, (A/C), SIMV, SIGH, CPAP, PEEP
    Respiratory rate 5 to 60 bpm
    I:E ratio
    Air compressor
    Inspiratory time
    Minute volume
    Display LCD (large)
    Pressure limit
    Medical grade O2 supply
    SIGH
    Over pressure relief ≤ 72 hpa
    Adjustable oxygen concentration 40 - 100 %
    Backup power supply
  • Features

    • Portable ventilator machine
      Multifunctional
      It consist ventilator, O2 cylinder, breathe circuit, special bracket
      More accuracy
      Easy to carry ( transport )
compare product
  • Specification

    Oxygen Concentration 48% to 100%
    Breathing Ratio 2:1 to 1:4
    Tidal Volume 0 to 1500 ml
    Respirator Rate 4 to 99/min
    Monitoring Display High-definition LCD liquid crystal display, the size of the LCD screen is not less than 100×55 (mm)
    Trigger Sensitivity - 20 to 0 cm H2O
    Positive End-Expiratory Pressure 5 to 20 cm H2O
    Maximum Safe Pressure of Gas System 6 kPa
    Air Pressure 280 to 600 kPa
    Whole Machine Noise Not more than 65 dB (A)
    Ventilation Mode A/C, SIGH, SIMV, SPONT, Manual
    Rated Pressure 0.4 MPa
    Pressure Range 0.28 MPa to 0.60 MPa
    Inhalation/Exhalation Impedance No more than 0.6 kPa at 30 L / min flow rate
    Airway Pressure Upper Limit Alarm 2 kPa to 6kPa
    Airway Pressure Lower Limit Alarm 0 kPa to 2 kPa
    Low Tidal Volume Alarm 50 mL to 150 mL
    Tidal Volume VT 0 to 1500 mL; Resolution: 1 mL
    Respiration Frequency F 4 to 60 bpm, Resolution/Increment: 1 bpm; range of SIMV is 2 to 30 bpm
    Fio2 Oxygen Concentration 48 % to 100 %, continuously adjustable
    Peak Pressure Peak 0 to 6 kPa
    Breathing Ratio I: E: 2 1 to 1: 8 is adjustable
    Trigger Sensitivity psens - 2 kPa to 0 kPa; Resolution/Increment: 0.1 kPa
    PEEP (Optional) 0 to 2 kPa
    Minute Ventilation Maximum not less than 18 liters / minute
    System Compliance No more than 4 mL / 100 Pa
    Input Current 0.125
    Power Supply Voltage AC 220 V, 50 Hz; DC DC12 V; built-in DC12V lithium battery pack
    Dimension (W×D×H) 300×170×175 mm
    Weight 3.5 kg
  • Features

    • Microcomputer control and Pneumatic electric control
      Different power sources like vehicle power and mains
      Built-in lithium battery pack, continuous running time is not less than 3 hours after the battery is fully charged
      Designed for first aid, equipped with a multi-purpose rack, easy to carry
      Ergonomic design and flat user interface
      Easy to clean, maintain and convenient to use
      Integrated with alarm for asphyxia, continuous pressure, low tidal volume and low air pressure
compare product
  • Specification

    Ventilation Modes CPAP, S, T, S/T, PC, VT control
    Frequency Adjusting Range 3 bpm to 40 bpm
    Frequency Increment 1 bpm
    Inspiration Time Adjusting Range 0 to 3 s
    Inspiration Increment 0.1 s
    IPAP Adjusting Range 4 cm H2O to 25 cm H2O
    IPAP Increment 0.5 cm H2O
    EPAP Adjusting Range 4 cm H2O to 20 cm H2O
    EPAP Increment 0.5 cm H2O
    CPAP Adjusting Range 4 cm H2O to 20 cm H2O
    CPAP Increment 0.5 cm H2O
    Ramp Time Adjusting Range 0 to 60 min
    Ramp Time Increment 1 min
    Rise Time Adjusting Range 0.1 s to 0.5 s
    Rise Time Increment 0.1 s
    Inspiration Trigger Adjusting Range Auto adjusting, 1 to 3
    Inspiration Trigger Increment 1
    Expiration Trigger Adjusting Range Auto adjusting, 1 to 3
    Expiration Trigger Increment 1
    Flex Adjusting Range OFF, 1 to 3
    Flex Increment 1
    Humidifier Adjusting Range 0 to 5
    Humidifier Increment 1
    Peak 0 to 30 cm H2O
    Graphical Display Airway pressure histogram
    Low Ventilation 0 to 15 L/min
    High Airway Pressure 20 cm H2O to 30 cm H2O
    High Frequency 1 bpm to 99 bpm
    Low Frequency  1 bpm to 60 bpm
    Suffocation Warning 8 s to 12 s
  • Features

    • Ergonomic design and flat user interface
      Five lockable casters for easy mobility
      Easy to clean, maintain and convenient to use
      Graphical display of airway pressure histogram
      Electrically controlled and pneumatically powered system
      Built in with suffocation alarm, high and low frequency, low ventilation and highway airway pressure
      Incorporated with inspiration trigger adjusting range and expiration trigger adjusting range
      Integrated with protection and alarm system