Hematology Analyzers

Our Hematology Analyzers feature advanced five and three part differentiation of WBCs. Fabricated from high quality components meeting standard clinical requirements. High throughput with efficient sampling. Our products are ISO and CE approved and certified.

compare product
  • Specification

    Output 35 samples / hrs.
    Channels Single
    Assay items 23 parameters
    Sample volume Venous : 9.8 µl
    Pre diluted: 20 µl
    Low sample volume 10 µl – 40 µl
    Aperture diameter
    Orientation Non-portable
    Operational mode Figure button, mouse, international Key-board
    Technology Advanced digital ARM Intelligent
    Test principle
    Display 8.4 inch TFT ( color )
    Measuring principle Electrical resistance, supercritical fluid technology
    Data storage 10,000 samples + 3 histograms
    Printer Internal thermal sensitive or external
    Working temperature
    Humidity
    Power supply
  • Features

    • Sampling rate - 35 samples per hour
      23 parameter setting with 3 part differentiation of WBCs
      Automatic sampling and probe cleaning
      Automated sample diluting, mixing, rinsing, clog cleaning
      Precised output with less blood sample consumption
      Electrical resistance for counting and SFT method
      Real time result monitoring
      3 operational modes : Figure button, mouse, international Key-board
      Advanced digital ARM intelligent technology
      Internal thermal sensitive or external printer
compare product
  • Specification

    Output 60 samples / hrs.
    Channels Double
    Assay items 23 parameters
    Sample volume Venous : 9.8 µl
    Pre diluted: 20 µl
    Low sample volume 10 µl – 40 µl
    Aperture diameter
    Orientation Portable
    Operational mode Figure button, mouse, international Key-board
    Technology Advanced digital ARM Intelligent
    Test principle
    Display 8.4 inch TFT ( color )
    Measuring principle Electrical resistance, supercritical fluid technology
    Data storage 10,000 samples + 3 histograms
    Printer Internal thermal sensitive or external
    Working temperature
    Humidity
    Power supply
  • Features

    • Sampling rate - 60 samples per hour
      23 parameter setting with 3 part differentiation of WBCs
      Automatic sampling and probe cleaning
      Automated sample diluting, mixing, rinsing, clog cleaning
      Precised output with less blood sample consumption
      Electrical resistance for counting and SFT method
      Real time result monitoring
      3 operational modes : Figure button, mouse, international Key-board
      Advanced digital ARM intelligent technology
      Internal thermal sensitive or external printer
compare product
  • Specification

    Output 35 samples / hrs.
    Channels
    Assay items 20 parameters
    Sample volume Normal mode : 10 µl
    Prediluted mode : 20 µl
    Low sample volume
    Aperture diameter WBC : 100 µm
    RBC, PLT : 70 µm
    Orientation
    Operational mode
    Technology
    Test principle Impedance : WBC, RBC, PLT
    Spectrophotometry : HGB
    Display 8 – inch TFT
    Measuring principle
    Data storage
    Printer
    Working temperature 18 ° C to 35 ° C
    Humidity 40 % to 80 % RH
    Power supply 175 / 265 V ( AC )
  • Features

    • 20 parameter setting with 3 part differentiation of WBCs
      Sampling rate – 35 samples per hour
      Use diluent and lyse
      Impedance method : WBC, RBC, PLT
      Spectrophotometry method : HGB
      Two narrow apertures incorporated
      Input : Keyboard , mouse
      Auto adaptive to the input voltage
      Printer – Internal thermal sensitive / External
compare product
  • Specification

    Output 60 samples / hrs.
    Channels
    Assay items 20 parameters
    Sample volume Normal mode : 10 µl
    Prediluted mode : 20 µl
    Low sample volume
    Aperture diameter WBC : 100 µm
    RBC, PLT : 70 µm
    Orientation
    Operational mode
    Technology
    Test principle Impedance : WBC, RBC, PLT
    Spectrophotometry : HGB
    Display 8 – inch TFT
    Measuring principle
    Data storage
    Printer
    Working temperature 18 ° C to 35 ° C
    Humidity 40 % to 80 % RH
    Power supply 175 / 265 V ( AC )
  • Features

    • 20 parameter setting with 3 part differentiation of WBCs
      Sampling rate – 60 samples per hour
      Use diluent and lyse
      Impedance method : WBC, RBC, PLT
      Spectrophotometry method : HGB
      Two narrow apertures incorporated
      Input : Keyboard , mouse
      Auto adaptive to the input voltage
      Printer – Internal thermal sensitive / External
compare product
  • Specification

    Output 60 samples / hrs.
    Assay items 22 parameters
    Sample volume Whole blood : 13 µl Prediluted: 20 µl
    Measuring principle Electro impendency, Photometric analysis
    Input Key pad
    Operation mode Automatic
    Calculation (QC) X,SD, CV %,
    Accuracy WBC ≤ 2 % RBC ≤ 1.4 % PCT ≤ 3.0% PLT ≤ 5.0 % HGB≤1.5 % MPV≤1.0 % HCT≤2.0 % MCHC≤2.0 %
    Power supply 110 / 220 V (AC) ; 50 / 60 Hz
    Data storage 200,000 results including histograms
    Display 10.4” LCD
    Dimension 430 × 320 × 505 mm
    Weight 20 kgs
  • Features

    • 22 parameters with 60 samples per hour
      3 part differentiation of WBCs
      Automatic probe washing
      Automated self-checking and warming
      Data input : Key pad
      Automatic calculation and saves data
      External or Internal thermal printer
compare product
  • Specification

    Output 80 Samples / hr.
    Parameters 24 parameters
    Operating temperature 18 to 30 ° C
    Analysis mode CBC, CBC + Differential
    Test principle Semiconductor laser flow cytometry combined with cytochemical staining
    Impedance
    Cyanide free colorimetry
    Sample Whole blood, prediluted blood
    Calculation (QC) X, X-B, L-J, X-L-J, totaling 12 documents, 400 results
    Relative humidity < 75%
    Power supply 100 / 240 V ; 50 / 60 Hz
  • Features

    • 5 parts differentiation for WBCs
      Parameters : WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#, RDW-SD, RDW-CV, PDW, MPV, PCT, P-LCR
      10 different research parameters
      Test principle : Semiconductor laser flow cytometry combined with cytochemical staining, Impedance, Cyanide free colorimetry
      Automatic sampling coupled with emergency access position
      External computer
      Preprogramed or user-defined printing format
      External printer, mouse, keyboard, USB driver
      Implement multiple quality control method
      Stores histograms, scattered plot, patient results and information
compare product
  • Specification

    Output ≥ 60 samples / hr
    Assay type 20 parameters + 3 color histograms
    Sample volume Venous : 9.6 µL
    Capillary : 9.6 µL
    Prediluted : 20 µL
    Relative humidity 10 to 90 %
    Test principle Electrical resistance
    Hemiglobincyanide method
    SFT method
    Calculation (QC) L-J, mean, X-B, SD, CV, QC
    Precision WBC ≤ 2.5 %RBC ≤ 2.0%HGB ≤ 1.5 %
    MCV ≤ 0.4 %PLT ≤ 5.0 %
    Display 10.4 inch LCD
    Storage 35,000 results inclusive of histograms
    Carryover WBC / RBC / HGB , 0.5 % , PLT < 1 %
    Operating temperature 15 to 35 ° C
    Power supply 100 / 240 V (AC) 50 / 60 Hz
  • Features

    • 20 parameter setting with 3 part differentiation of WBCs
      Sampling rate – 60 samples per hour
      Whole or diluted forms of blood sample
      Double passage counting with independent HGB measurement
      Operation mode : Windows operation system ( keyboard and mouse )
      Stores 35,000 results including histograms
      Implement multiple quality control method
      Internal thermal sensitive or external printer
compare product
  • Specification

    Output 60 samples per hour
    Assay type 20 parameters + 3 color histograms
    Sample volume Predilute : 20μL
    Whole blood : 15μL
    Relative humidity 30% to 85%
    Test principle Coulter Principle
    Colorimetry hemoglobin determination
    Aperture diameter WBC : 80 μm
    RBC / PLT : 70 μm
    Precision ( CV % ) WBC = 2.5 (7.0 to 15.0), RBC = 2.5 (3.50 to 6.00)
    HGB = 1.5 (110 to 180), MCV = 0.5 (80.0 to 110.0)
    PLT = 5.0 (200 to 500)
    Display 8.0”color LCD display
    Storage 16000 results including histograms
    Carryover WBC / RBC / HGB < 0.5% ,  PLT< 1%
    Operating temperature 15 ° C to 30 ° C
    Power supply 100 / 240 V (AC ) ; 50 / 60 Hz
    Dimension 440 × 350 × 440 mm
    Weight 17 kg
  • Features

    • 20 parameter setting with 3 part differentiation of WBCs
      Sampling rate – 60 samples per hour
      Dual aperture for WBC and RCB / PLT
      Whole or diluted forms of blood sample
      Automatic diluting, lyzing, mixing, rinsing
      Automated sample probe cleaning
      Operation mode : Windows operation system ( keyboard and mouse )
      Touch screen LCD display for parameter setting
      Stores 16000 results including histograms
      Implement multiple quality control method
      Internal thermal sensitive printer