Our Hematology Analyzers feature advanced five and three part differentiation of WBCs. Fabricated from high quality components meeting standard clinical requirements. High throughput with efficient sampling. Our products are ISO and CE approved and certified.
Output | 35 samples / hrs. |
---|---|
Channels | Single |
Assay items | 23 parameters |
Sample volume |
Venous : 9.8 µl Pre diluted: 20 µl |
Low sample volume | 10 µl – 40 µl |
Aperture diameter | |
Orientation | Non-portable |
Operational mode | Figure button, mouse, international Key-board |
Technology | Advanced digital ARM Intelligent |
Test principle | |
Display | 8.4 inch TFT ( color ) |
Measuring principle | Electrical resistance, supercritical fluid technology |
Data storage | 10,000 samples + 3 histograms |
Printer | Internal thermal sensitive or external |
Working temperature | |
Humidity | |
Power supply |
Output | 60 samples / hrs. |
---|---|
Channels | Double |
Assay items | 23 parameters |
Sample volume |
Venous : 9.8 µl Pre diluted: 20 µl |
Low sample volume | 10 µl – 40 µl |
Aperture diameter | |
Orientation | Portable |
Operational mode | Figure button, mouse, international Key-board |
Technology | Advanced digital ARM Intelligent |
Test principle | |
Display | 8.4 inch TFT ( color ) |
Measuring principle | Electrical resistance, supercritical fluid technology |
Data storage | 10,000 samples + 3 histograms |
Printer | Internal thermal sensitive or external |
Working temperature | |
Humidity | |
Power supply |
Output | 35 samples / hrs. |
---|---|
Channels | |
Assay items | 20 parameters |
Sample volume |
Normal mode : 10 µl Prediluted mode : 20 µl |
Low sample volume | |
Aperture diameter |
WBC : 100 µm RBC, PLT : 70 µm |
Orientation | |
Operational mode | |
Technology | |
Test principle |
Impedance : WBC, RBC, PLT Spectrophotometry : HGB |
Display | 8 – inch TFT |
Measuring principle | |
Data storage | |
Printer | |
Working temperature | 18 ° C to 35 ° C |
Humidity | 40 % to 80 % RH |
Power supply | 175 / 265 V ( AC ) |
Output | 60 samples / hrs. |
---|---|
Channels | |
Assay items | 20 parameters |
Sample volume |
Normal mode : 10 µl Prediluted mode : 20 µl |
Low sample volume | |
Aperture diameter |
WBC : 100 µm RBC, PLT : 70 µm |
Orientation | |
Operational mode | |
Technology | |
Test principle |
Impedance : WBC, RBC, PLT Spectrophotometry : HGB |
Display | 8 – inch TFT |
Measuring principle | |
Data storage | |
Printer | |
Working temperature | 18 ° C to 35 ° C |
Humidity | 40 % to 80 % RH |
Power supply | 175 / 265 V ( AC ) |
Output | 60 samples / hrs. |
---|---|
Assay items | 22 parameters |
Sample volume | Whole blood : 13 µl Prediluted: 20 µl |
Measuring principle | Electro impendency, Photometric analysis |
Input | Key pad |
Operation mode | Automatic |
Calculation (QC) | X,SD, CV %, |
Accuracy | WBC ≤ 2 % RBC ≤ 1.4 % PCT ≤ 3.0% PLT ≤ 5.0 % HGB≤1.5 % MPV≤1.0 % HCT≤2.0 % MCHC≤2.0 % |
Power supply | 110 / 220 V (AC) ; 50 / 60 Hz |
Data storage | 200,000 results including histograms |
Display | 10.4” LCD |
Dimension | 430 × 320 × 505 mm |
Weight | 20 kgs |
Output | 80 Samples / hr. |
---|---|
Parameters | 24 parameters |
Operating temperature | 18 to 30 ° C |
Analysis mode | CBC, CBC + Differential |
Test principle |
Semiconductor laser flow cytometry combined with cytochemical staining Impedance Cyanide free colorimetry |
Sample | Whole blood, prediluted blood |
Calculation (QC) | X, X-B, L-J, X-L-J, totaling 12 documents, 400 results |
Relative humidity | < 75% |
Power supply | 100 / 240 V ; 50 / 60 Hz |
Output | ≥ 60 samples / hr |
---|---|
Assay type | 20 parameters + 3 color histograms |
Sample volume |
Venous : 9.6 µL Capillary : 9.6 µL Prediluted : 20 µL |
Relative humidity | 10 to 90 % |
Test principle |
Electrical resistance Hemiglobincyanide method SFT method |
Calculation (QC) | L-J, mean, X-B, SD, CV, QC |
Precision |
WBC ≤ 2.5 %RBC ≤ 2.0%HGB ≤ 1.5 % MCV ≤ 0.4 %PLT ≤ 5.0 % |
Display | 10.4 inch LCD |
Storage | 35,000 results inclusive of histograms |
Carryover | WBC / RBC / HGB , 0.5 % , PLT < 1 % |
Operating temperature | 15 to 35 ° C |
Power supply | 100 / 240 V (AC) 50 / 60 Hz |
Output | 60 samples per hour |
---|---|
Assay type | 20 parameters + 3 color histograms |
Sample volume |
Predilute : 20μL Whole blood : 15μL |
Relative humidity | 30% to 85% |
Test principle |
Coulter Principle Colorimetry hemoglobin determination |
Aperture diameter |
WBC : 80 μm RBC / PLT : 70 μm |
Precision ( CV % ) |
WBC = 2.5 (7.0 to 15.0), RBC = 2.5 (3.50 to 6.00) HGB = 1.5 (110 to 180), MCV = 0.5 (80.0 to 110.0) PLT = 5.0 (200 to 500) |
Display | 8.0”color LCD display |
Storage | 16000 results including histograms |
Carryover | WBC / RBC / HGB < 0.5% , PLT< 1% |
Operating temperature | 15 ° C to 30 ° C |
Power supply | 100 / 240 V (AC ) ; 50 / 60 Hz |
Dimension | 440 × 350 × 440 mm |
Weight | 17 kg |