Zimed offer Automatic and semi-automatic biochemistry analyzers to measure different components such as sugar, cholesterol, protein, enzyme present in biological samples. Automatic testing process reduces the test time and also human effort. Our analyzer is in accordance with Annex II and III of the 98/79/EC.
Assay Mode |
End point, Kinetic, Fixed time, Immuno-turbidimetry, 1 - 2 reagent, Multi-standard, Reagent / Serum blank, etc. |
---|---|
Wavelength | 340 nm to 810 nm |
Sample Volume | 1 to 100 µl ( 0.1 µl / step ) |
Reagent Volume | 1 to 400 µl ( 1 µl / step ) |
Assay Item | 40 Assay |
Sample Position | 30 |
Reagent Position | 40 |
Reaction Time | 0 to 999 sec |
Cuvette | UV- transmitted plastic, Quartz glass |
Absorbance | 0.0001 Abs |
Repeatability ( CV % ) |
≤ 2 % |
Alarm | Collision, Reagent / Sample insufficiency, Waste container |
Calibration | Linear, Non-linear, Multi-standard, K-factor |
Power Supply | 220 V / 50 Hz |
Dimensions | 650 × 530 × 520 mm |
Weight | 40 kg |
Assay Method | End-point, Kinetic, Two-point, Double-reagent, Double-wavelength , Multi-standard |
---|---|
Output | 200 samples / hr |
Sample Volume | 1 µl to 50 µl ( 0.5 µl /step ) |
Sample Tray | 18 position |
Sample Probe | |
Reagent Volume | 180 µl to 600 µl ( 1 µl / step ) |
Reagent Position | 26 position |
Reaction Tray | 60 acrylic cuvette |
Reaction Volume | 180 µl to 500 µl |
Reaction Time | 12 min |
Light Source | Halogen-tungsten lamp |
Flow Cell | |
Filters | 8 |
Optical Wavelength | 340 nm to 690 nm |
Optical System | |
Photometric Measuring Range ( OD ) | |
Absorbance Range | 0 to 3.0 Abs |
Calibration | |
Dilution | 0.11111111111111 |
Water Consumption | 1 L / hr to 2 L / hr |
Operating Temperature | 10 °C to 35 °C |
Dimensions | 548 × 422 × 383 mm |
Weight | ≤ 23 kg |
Output | 200 samples / hour |
---|---|
Assay Method | End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration |
Wavelength | 340 nm, 405 nm, 450 nm, 510 nm, 546 nm, 578 nm, 630 nm, 700 nm |
Test Method | Colorimetry, Turbidimetry |
Sample Tray | 42 positions |
Reagent Tray | 25 positions |
Sample Volume | 2 to 50 µl ( 0.1 µl increment ) |
Reagent Volume |
R1 : 25 to 300 µl R2 : 10 to 150 µl ( 0.1 µl increment ) |
Reagent Refrigeration | 24 hr. non-stop refrigeration at 4 to 15 ° C |
Reaction Tray | Rotating tray, 120 cuvettes |
Reaction Volume | 180 to 500 µl |
Light Source | Halogen lamp ( 12 V / 35 W ) |
Absorbance Range | 0 to 3.500 Abs |
Resolution | 0.0001 Abs |
Temperature | 15 to 30 ° C |
Humidity | 35 to 80 RH % |
Power Supply | 220 V ± 22 V ( 50 Hz ± 1 Hz ) |
Water Consumption | 5 L / hr. |
Dimensions | 750 × 520 × 600 mm |
Weight | 45 kg |
Output | |
---|---|
Assay Method | |
Wavelength | |
Test Method | Colorimetry, Turbidimetry |
Sample Tray | 60 positions |
Reagent Tray | 60 positions |
Sample Volume | |
Reagent Volume | 2 to 500 µl |
Reagent Refrigeration | |
Reaction Tray | 81 cuvettes |
Reaction Volume | 150 µl |
Light Source | Halogen-tungsten lamp |
Absorbance Range | |
Resolution | |
Temperature | 10 to 30 ° C |
Humidity | Less than 70 % |
Power Supply | 220 V ± 22 V ( 50 Hz ± 1 Hz ) |
Water Consumption | Less than 6 L / hr. |
Dimensions | 782 × 581 × 545 mm |
Weight | 60 kg |
Aspiration volume | 200 µl to 2000 µl |
---|---|
Flow cell | 32 µl |
Assay type | Kinetics, Bi-chromatic, End-point, Differential, Fixed time, Multi-standard |
Wavelength | 340 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm, 670 nm |
Light source | 6 V / 10 W Halogen lamp |
Optical diameter | 1 cm |
Band width | < 8 nm |
Cross contamination rate | < 1% |
Temperature control | 25 °C, 30 °C, 37 °C |
Operating temperature | 10 °C to 40 °C |
Relative humidity | < 85 % |
Power supply | 220 V / 110 V ( AC ); 50 Hz / 60 Hz |
Assay type | End-point, Two point, Kinetic, Reagent blank sample blank, Immunity nephelometry and Multiplication selectable calibration methods |
---|---|
Wave length | 340 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm, 670 nm |
Flow cell | 32 µl quartz / metal flow cell |
Aspirate volume | >100 µl |
Sample volume | |
Light source | 6V / 10 W Halogen lamp |
Band width | 8 nm |
Absorbance range | 0 to 3.000 Abs |
Repeatability ( CV % ) | ≤ 1 % |
Incubator ( working temperature ) | 37 °C, 30 °C, 25 °C |
Temperature precision | ± 0.1 °C |
Display | 7” TFT |
Power supply | 250 V / 100 V ( AC ) ; 50 Hz / 60 Hz |
Assay type | Kinetic, End point, Two point and Absorbance |
---|---|
Wave length | 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 630 nm |
Flow cell | 32 µl quartz glass |
Aspirate volume | |
Sample volume | 0 to 3000 µl ( ≥ 500 µl recommended ) |
Light source | 6V / 10 W Halogen lamp |
Band width | ≤ 10 nm |
Absorbance range | 0 to 4.500 Abs |
Repeatability ( CV % ) | < 1 % |
Incubator ( working temperature ) | 37 °C, 30 °C, 25 °C |
Temperature precision | ± 0.1 °C |
Display | 7” TFT |
Power supply | 240 V / 100 V ( AC ) ; 50 Hz / 60 Hz |
Wave length | 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 630 nm |
---|---|
Assay mode |
End-point, Kinetics, Fixed time absorbance, Turbidimetry, Linear and Non-linear calibration |
Temperature control | 25 °C, 30 °C, 37 °C |
Flow cell | 32 µl |
Absorbance range | 0 to 3.000 Abs |
Resolution | 0.0001 Abs |
Half band width | < 0.3 % at 340 nm |
Power |
220 V / 110 V ± 10 % ( AC ) 50 Hz ± 2 % |
Temperature | 10 °C to 30 °C |
Humidity | ≤ 70 % |
Dimensions | 420 × 380 × 170 mm |
Weight | 8.5 Kg |