Hemodialysis Machine ZHD-A10

Hemodialysis Machine ZHD-A10

Hemodialysis Machine ZHD-A10 is an effective device that was designed to simplify dialysis and improve patient outcomes and experience. It helps to facilitate rapid and trouble-free dialysis offering a Dialysate flux of 300 to 800 mL/min. Hemodialysis is a treatment that replaces the work of the own kidneys to clear wastes and extra fluid from the blood. Intended with a special filter, dialyzer, or artificial kidney. Safety features with an in-built alarm system detect the bubble or any blood leaks ensuring accurate and reliable results.

Product Enquiry View Catalog
Specification
Dialysate temperature 34.0 °C to 39.0 °C
Dialysate flux 300 to 800 ml/min
Dialysate concentration 12.1 mS/cm to 16.0 mS/cm, ± 0.1 mS/cm
UF rate Flow range 0 ml/h to 4000 ml/h
Dialysate Resolution ratio 1 ml
Dialysate Precision ±30 ml/h
Extracorporeal Venous pressure -180 mm Hg to +600 mmHg, ±10 mm Hg
Extracorporeal Arterial pressure -380 mm Hg to + 400 mm Hg, ± 10 mm Hg
TMP pressure -180 mm Hg to + 600 mm Hg, ±20 mm Hg
Blood pump flow range 20 ml/min to 400 ml/min(diameter:Ф6 mm)
Spare pump flow range 30 ml/min to 600 ml/min(diameter:Ф8 mm)
Resolution ratio 1 mL
Heparin Pump Syringe size 20, 30, 50 mL
Heparin pump Flow range 0 ml/h to 10 ml/h
Heparin pump Resolution ratio 0.1 ml
Water input pressure 0.15 MPa to 0.6 MPa, 21.75 P.S.I. to 87 P.S.I
Water input temperature 10℃ to 30℃
Working environment 10℃ to 30℃ at relative humidity of no more than 70%
Power 1500 W
Power supply AC220V/50Hz / 60Hz, 10A
Dimension (L×W×H) 380 × 400 × 1380 mm
Weight 88 Kg
Features
  • Integrated with Intelligent Double Operation System controlling and monitoring the various parameters
  • Designed with a TFT LCD touch Screen with a user-friendly button interface
  • Offers a Dialysate temperature with a preset range of 34.0℃ to 39.0℃, ±0.5℃
  • Adopts Blood leak detection with Photochromic property
  • In-built alarm system alerts when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal to or more than 1ml per liter of dialysate
  • The bubble detection system detects a single air bubble volume is more than 200µl at 200ml/min blood flow with an ultrasonic alarm
  • Intended with conductivity composed of ±0.5% acoustic-optic

Applications

Hemodialysis machine is applicable for chronic renal failure and other blood purification treatments. This device should be used in medical units specially designed, produced, and sold for renal failure patients to receive hemodialysis, which is not allowed to be used for other purposes.